The NextPS sensor series has been designed to meet the highest standards. With 3 patents offering the best quality / size / price compromise, NextPS provides real time particles concentration in particles /m³:
- Channel 1 : >0.3 μm
- Channel 2 : >0.5 μm
- Channel 3 : >1.0 μm
- Channel 4 : >2.5 μm
- Channel 5 : >5.0 μm
Thanks to its patented air flow control technology, NextPS ensures 1 year of maintenance-free measurements.
UART and / or Modbus connection.
Advantages
- No loss of performance due to fouling
- No maintenance or calibration during the life of the sensor.
- Stable response
- Lowest cost of operation on the market
- Ability to deport sample taking through the tubing adapter on the air inlet.
Measurement accuracy
NextPS patented technology provides the most accurate particle measurement solution on the market.
Smart & high reactivity
Automatic learning algorithms to improve measurements over time and allow peak detection in less than a second.
Applications
- Clean Room
- Operating theatre
- Controlled Environment
- Air filtration systems
Software
https://tera-sensor.com/resources/
How to wire NextPS?
- FTDI Chip, 3.3 V TTL Wire End USB to UART Cable (RS Stock No. 429-303 / Mfr. Part No. TTL-232R-3V3-WE)
- Molex PicoBlade Wire to Board Cable (RS Stock No. 125-0742 / Mfr. Part No. 15134-0603)
Parameters measurement PM1, PM2.5 et PM10
Measures units Particles Particles : pcs/m³
Technology of detection Optical Particle Counting
Measure range 0 to 3.3.109 pcs/m³
Linearity error < 5%
Size Detection Range 0.3 μm to 10 μm
Communication protocol UART/Modbus
Frequency measure Second
Communication options Running average 10 - 60 - 900 sec
Power supply 5.0 V
Lifespan (MTTF) 10 000 hours
Additional parameters Temperature and relative humidity : Available.