Solid state relay with diagnostic output
Solid state power relay with charge, network and relay output diagnostics.
TMS
2
technology thyristor output ensures longevity.
Input 7 → 30 Vdc with green LED control indicator.
N/C static state contact
Very low synchronism level.
Spring-technology pull-out input connectors.
Solid state relays must be mounted on a heatsink.
ref. Celduc
Switching current
Switching voltage
Control voltage
SOD845180
50 A
50 → 265 Vac
7 → 30 Vac
SOD865180
50 A
150 → 510 Vac
7 → 30 Vac
Input characteristics
Non-operating voltage:
3 V
Control current:
9 → 21 mA
Output characteristics
Dynamic resistance:
12 mΩ
Input / output isolation voltage:
4000 Vrms
Closing time:
10 ms
Opening time:
10 ms
Operating frequency:
0.1 → 400 Hz
Dimensions (mm):
58 x 29 x 45
WF070000
RthJC =
0.75 k / W
Dimensions (mm):
110 x 100 x 100
Weight (kg):
1.2
WF050000
RthJC =
0.55 k / W
Dimensions (mm):
110 x 200 x 100
Weight (kg):
2.84
Standards
EN60947-4-3
Instantaneous Switching
Note
Temperature can affect current rating; please consult the data sheet for potential derating.