This is manufactured by IXYS. The manufacturer part number is CLA30MT1200NPZ-TRL. It is assigned with possible HTSUS value of 8541.30.0080. The product is rohs3 compliant. While the maximum voltage - gate trigger includes 1.3 v. The product has -40°c ~ 150°c (tj) operating temperature range. Moreover, the product comes in to-263-3, d2pak (2 leads + tab), to-263ab. The maximum hold current is 50 ma. In addition, it is reach unaffected. The maximum 33 a of on state current. It has an off state voltage of 1.2 kv. The product is available in single configuration. The ixys's product offers user-desired applications. Its typical moisture sensitivity level is 3 (168 hours). The maximum gate triggering current is 40 ma. It has a long 18 weeks standard lead time. Non rep. current with 50, 60Hz surge included 170a, 185a. The product is available in surface mount configuration. The product dt-triac™, is a highly preferred choice for users. to-263hv is the supplier device package value. In addition, tape & reel (tr) is the available packaging type of the product. It is a standard triac. Moreover, it corresponds to cla30, a base product number of the product. The product is designated with the ear99 code number.