Deliver to
United Kingdom
Enjoy 5% savings by entering the code 'SAVE5' when you spend £50 or more!
This is manufactured by Omron Automation and Safety. The manufacturer part number is MY4I4N AC12. While the must release voltage is a 3.6 vac. It is assigned with possible HTSUS value of 8536.41.0020. The coil voltage of the product is 12vac. Moreover, it has plug in terminal style. The product has -55°c ~ 70°c operating temperature range. It is approved by ce, csa, ur, vde. It holds up to 46 ohms coil resistance. It has a coil current of 260.9 ma. The coil is a non latching type. The product's switching voltage is 250vac, 125vdc - max. On the other hand, 9.6 vac is the given crucial/must operating voltage. This is basically a general purpose. It also has a 4pdt (4 form c) contact form. Its typical moisture sensitivity level is 1 (unlimited). The operating time of the product is 20 ms. It has a contact current rating of 3 a. The splendid features of the product include latching lever. The product is available in socketable configuration. The product my, is a highly preferred choice for users. While 20 ms is its release time. In addition, bulk is the available packaging type of the product. The product is made from sturdy silver (ag), gold (au) materials. Moreover, it corresponds to my4i4, a base product number of the product. The product is designated with the ear99 code number.
For more information please check the datasheets.
Basket Total:
£ 0