This is manufactured by Omron Automation and Safety. The manufacturer part number is MKS3PIN-V-5 AC12. While the must release voltage is a 3.6 vac. It is assigned with possible HTSUS value of 8536.41.0050. The product is rohs compliant. The coil voltage of the product is 12vac. Moreover, it has plug in, 11 pin (octal) terminal style. The product has -25°c ~ 60°c operating temperature range. It is approved by csa, curus, tuv. It holds up to 13.7 ohms coil resistance. It has a coil current of 193 ma. The coil is a non latching type. The product's switching voltage is 250vac, 30vdc - max. On the other hand, 9.6 vac is the given crucial/must operating voltage. This is basically a general purpose. It also has a 3pdt (3 form c) contact form. Its typical moisture sensitivity level is 1 (unlimited). The operating time of the product is 20 ms. It has a contact current rating of 10 a. The splendid features of the product include lighted indicator, mechanical indicator, test button, varistor. The product is available in socketable configuration. The product mk-s, is a highly preferred choice for users. While 20 ms is its release time. In addition, bulk is the available packaging type of the product. The product is made from sturdy silver tin indium (agsnin) materials. Moreover, it corresponds to mks3p, a base product number of the product. The product is designated with the ear99 code number.