Number of Outputs:
1
Load Regulation:
±0.2%
Isolation Voltage:
3kV dc
Standards Met:
cUL 60950-1, EN 50121-3-2, EN 50155, En 50155, EN 60950-1, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, MIL-HDBK-217F, UL
Mounting Type:
Through Hole
Package:
Half Brick
Maximum Temperature:
+100°C
Series:
RDL100
Input Voltage Range:
66 → 160 V dc
Length:
61mm
Railway Approved:
Yes
Isolated:
Yes
Width:
57.9mm
Depth:
12.7mm
Output Voltage:
12V dc
Minimum Temperature:
-40°C
Input Voltage Nominal:
110 V dc
Power Rating:
100W
Output Current:
8.3A
HTSUS:
8504.40.9580
RoHS Status:
ROHS3 Compliant
Supplier Device Package:
Half Brick
Power (Watts):
96 W
Current - Output (Max):
8.03A
Package / Case:
Half Brick
Voltage - Input (Min):
66V
Type:
Isolated Module
Applications:
ITE (Commercial), Railway
Voltage - Output 4:
-
Voltage - Output 1:
12V
Voltage - Output 2:
-
Voltage - Output 3:
-
Efficiency:
86.5%
Voltage - Input (Max):
160V
Package:
Box
Size / Dimension:
2.40" L x 2.28" W x 0.50" H (61.0mm x 57.9mm x 12.7mm)
Voltage - Isolation:
3 kV
Moisture Sensitivity Level (MSL):
1 (Unlimited)
Features:
Remote On/Off, OCP, OTP, OVP, SCP, UVLO
Mounting Type:
Through Hole
Series:
RDL100 (100W)
Operating Temperature:
-40°C ~ 100°C
Base Product Number:
RDL100110
Number of Outputs:
1
ECCN:
EAR99