Chauvin Arnoux F606 Clamp Meter, 3kA dc, Max Current 2000A ac CAT III 1500V

P01120966 Chauvin Arnoux F606 Clamp Meter, 3kA dc, Max Current 2000A ac CAT III 1500V
P01120966
Chauvin Arnoux

Product Information

Dimensions:
111 x 41 x 296mm
Power Source:
Battery
DC Current Measurement Resolution:
10mA
Maximum Conductor Size:
60mm
DC Current Measurement Range:
0.25 to 3000 A DC
AC Current Measurement Range:
0.25 to 2000 A AC
Width:
111mm
Battery Life:
>350 h
Resistance Measurement Resolution:
100mΩ
AC Current Measurement Resolution:
10mA
True RMS:
Yes
AC Voltage Measurement Range:
0.15 to 1200 V AC
Absolute Maximum AC Voltage Measurement:
1200V ac
Model Number:
F606
Best AC Voltage Accuracy:
±(1% rdg + 3dgts)
Absolute Maximum AC Current Measurement:
2000A ac
Battery Type:
LR6
Absolute Maximum Resistance Measurement:
99.99kΩ
Maximum Operating Temperature:
+55°C
Non-Contact Voltage Detector:
No
Jaw Capacity Busbars:
60mm
Safety Category Level:
CAT III, CAT IV
Length:
296mm
Absolute Maximum DC Current Measurement:
3000A dc
Display Type:
Backlit LCD
Best Resistance Measurement Accuracy:
±1 % + 5 digits
Best DC Current Accuracy:
±(1% rdg + 3dgts)
Weight:
640g
AC Voltage Measurement Resolution:
10mV
Best AC Current Accuracy:
±(1% rdg + 3dgts)
Safety Category Voltage:
CAT III 1500 V, CAT IV 1000V
Absolute Maximum DC Voltage Measurement:
1700V dc
Height:
41mm
Safety Category:
CAT III 1500 V, CAT IV 1000V
Best DC Voltage Accuracy:
±(1% rdg + 3dgts)
DC Voltage Measurement Resolution:
10mV
Clamp Meter Type:
AC/DC Clamp Meter
Minimum Operating Temperature:
-20°C
Functions Measured:
AC Current, AC Voltage, Continuity, DC Current, DC Voltage, Diode, Frequency, Harmonics, In-Rush Current, Phase rotation, Power, Power Factor, Resistance
RoHs Compliant
Checking for live stock

This is F606 Clamp Meter 3kA dc Max Current 2000A ac CAT III 1500V manufactured by Chauvin Arnoux. The manufacturer part number is P01120966. The given dimensions of the product include 111 x 41 x 296mm. Moreover, the product gets power from battery. It has about 10ma DC current measurement resolution . Moreover, it has a maximum 60mm size conductor . In addition, it has a DC Current Measurement Range of 0.25 to 3000 a dc The AC Current Measurement Range of the product is 0.25 to 2000 a ac Furthermore, the product is 111mm wide. Its battery life is about >350 h . It has approximately 100mω resistance measurement resolution . In addition, it has about 10ma AC current measurement resolution . It has a True RMS feature yes . It has an AC Voltage Measurement Range of 0.15 to 1200 v ac Additionally, it has an absolute maximum 1200v ac voltage measurement . It has a model number f606. Its best AC voltage accuracy is about ±(1% rdg + 3dgts) . It has an absolute maximum 2000a ac current measurement . This lr6 battery is comparatively much efficient than common batteries. Moreover, it has an absolute maximum 99.99kω resistance measurement . It has a maximum operating temperature of +55°c. It includes a non-contact voltage detector no . The product has about 60mm jaw busbars capacity . Moreover, its safety category level is cat iii, cat iv . Its accurate length is 296mm. The product has an absolute maximum 3000a dc current measurement . It features a remarkable backlit lcd display. It exhibits a ±1 % + 5 digits best resistance measurement accuracy . Additionally, it has a ±(1% rdg + 3dgts) best DC current accuracy . The typical product's weight is 640g. Whereas, its AC voltage measurement resolution is 10mv . It has a ±(1% rdg + 3dgts) best AC current accuracy . Its safety category voltage is cat iii 1500 v, cat iv 1000v . Moreover, it has an absolute maximum 1700v dc voltage measurement . In addition, the height is 41mm. It provides robust safety and is complied with cat iii 1500 v, cat iv 1000v safety category. Moreover, it has a ±(1% rdg + 3dgts) best DC voltage accuracy . Its DC voltage measurement resolution is approximately 10mv . It has a/an ac/dc clamp meter type clamp meter . Whereas, the minimum operating temperature of the product is -20°c. Moreover, it has an ac current, ac voltage, continuity, dc current, dc voltage, diode, frequency, harmonics, in-rush current, phase rotation, power, power factor, resistance functions measured .

pdf icon
F606 user's manual EN(Technical Reference)
pdf icon
Sales brochure_EN(Technical Reference)

Reviews

  • Be the first to review.

FAQs

Yes. You can also search P01120966 on website for other similar products.
We accept all major payment methods for all products including ET25272601. Please check your shopping cart at the time of order.
You can order Chauvin Arnoux brand products with P01120966 directly through our website or call us at +44 (0) 3303 800 157 or email our support team at sales@enrgtech.co.uk.
Yes. Our products in Clamp Meters category are shipped in lowest possible time.
You will get a confirmation email regarding your order of Chauvin Arnoux F606 Clamp Meter, 3kA dc, Max Current 2000A ac CAT III 1500V. You can also check on our website or by contacting our customer support team for further order details on Chauvin Arnoux F606 Clamp Meter, 3kA dc, Max Current 2000A ac CAT III 1500V.
We use our internationally recognized delivery partners UPS/DHL. Collection of ET25272601 can also be arranged for the customer by international shipments through contacting our customer support team. Additionally, you can also search "Chauvin Arnoux" products on our website by using Enrgtech's Unique Manufacturing Part Number ET25272601.
Yes. We ship P01120966 Internationally to many countries around the world.