LF - S Series
Current transducers LF-S Series for the electronic measurement of currents: dc, ac, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. They are speciallly designed for industrial applications.
Measurement of ac, dc and pulsed currents
High Accuracy - Closed Loop
High Noise Immunity
Low Temperature Drift
Current Overload Capability
Optimised response time
Wide Frequency Bandwidth
Multiple Mounting Options
Body material plastic to UL94-V0
Operating temperature range -10 → +70°C
Series
Mounting
Isolation Test Voltage (kV)
Max Current Consumption (mA)
Thermal Drift
Linearity
Stock No.
LF 205-P
PCB
3.5
17
±0.4 mA (Max); ±0.12 mA (Typ)
451-1346
LF 205-S
Chassis
3.5
17
±0.4 mA (Max); ±0.12 mA (Typ)
451-1352
LF 305-S
Chassis
3
16
±0.3 mA (Max); ±0.1 mA (Typ)
451-1368
LF 306-S
Chassis
6
20
±0.64 mA (Max); ±0.24 mA (Typ)
451-1374
LF 505-S
Chassis
3
24
±0.4 mA (Max); ±0.1 mA (Typ)
451-1380
LF 1005-S
Chassis
3
20
±0.5 mA (Max); ±0.3 mA (Typ)
451-1396
LF 2005-S
Chassis
6
33
±0.4 mA (Max); ±0.2 mA (Typ)
451-1403
Dimensions
Height (mm)
Width (mm)
Depth (mm)
Weight (g)
LF 205-P
45
48
19.5
58
451-1346
LF 205-S
51.63
61
34.5
78
451-1352
LF 305-S
56.53
68
36.8
95
451-1368
LF 306-S
57.4
67.3
15.7
60
451-1374
LF 505-S
70
89
31
230
451-1380
LF 1005-S
94.8
110
34
500
451-1396
LF 2005-S
135
170
30
1500
451-1403