705 Loop Calibrator
Low cost calibration muscle The Fluke 705 Loop Calibrator is a cost-effective, integrated solution for calibration, repair and maintenance of current loops.
Features and Benefits
mA sourcing, simulation and measurement
0.02 % accuracy and 0.001 mA resolution
Simultaneous mA and % of span display
Selectable step or ramp outputs
24 V Loop supply with mA measure
0 V dc to 28 V dc measurement to check Loop Voltage
Removable battery door for quick battery replacement
Compact case with protective holster
Temperature range 18 to 28°C
Range
Resolution
Accuracy
Voltage Measure
0 to 28V
0.001V
0.025% Rdg
+ 1 LSD
mA Measure
0 to 24mA
0.001 mA
0.02% Rdg
+ 2 LSD
mA Source
0 to 24 mA
0.001 mA
0.02% Rdg
+ 2 LSD
Max load
1000Ω
Loop Supply
24Vdc
n/a
10%
General:
Maximum voltage
30V
Temp. coefficient
-10 to 18°C, 28 to 55°C, ±0.005% of range per °C
Supplied with
9V installed alkaline battery, AC70A alligator clips, C10 protective yellow holster Flex-Stand™, instruction sheet, TL75 safety-designed test lead set, NIST- traceable calibration report and data