Products Found: 20

Showing Results For: Safety Expansion Modules

Safety Expansion Modules

Safety expansion modules are used in modern industrial systems and are built to expand the performance of safety controllers smoothly. Expansion modules ensure the safe functionality of machinery, providing reliability and compliance with strict safety standards. Work environments can protect workers from harm by integrating safety modules and minimising the downtime caused by accidents. They provide the flexibility required for diverse applications across various industries.

Furthermore, they are mainly used to address the ever-growing safety demands of workspaces. These modules allow comprehensive monitoring and regulation of safety functions like emergency stops, light curtains, and safety gates. They simplify the addition of safety circuits, allowing businesses to comply with official safety standards, such as ISO 13849 and IEC 6206.

How Do Safety Expansion Modules Work?

Safety expansion modules extend the abilities of safety controllers by precision monitoring input signals from safety devices like light curtains or emergency stops. They are responsible for processing these signals to identify hazards and trigger safety responses like stopping the machinery or isolating electrical energy. When integrated with safety controllers, safety expansion modules provide detailed monitoring and control while confirming compliance with safety regulations. Safety modules frequently comprise self-diagnostics to detect faults, ensuring the operating system’s reliability and workspace safety.

What Makes Safety Expansion Modules So Significant?

  • Improve overall workplace safety.
  • Straightforward integration into existing systems.
  • Cost-effective solution for scaling safety controls.
  • Compliant with UK health and safety regulations.
  • Enhanced protection for operators and machinery.
  • Reduces chances associated with equipment failure.

Safety Expansion Module Types

  • Relay-Based Modules: Dependable for basic safety functions.
  • Programmable Modules: Flexible and suitable for complex applications.
  • Input/Output Modules: Efficient for monitoring multiple safety devices.

Standout Features Include

  • Plug-and-play convenience.
  • Adaptable with various safety devices.
  • Compact layout for space efficiency.
  • High response speed.

Versatile Uses of Safety Expansion Modules

  • Manufacturing and Assembly Lines.
  • Automated Robotics Systems.
  • Packaging and Material Handling.
  • Energy and Utility Sectors.

FILTERS
Filters
Showing
1 -
Enrgtech #
Manufacturer Part No
Name
Availability
Price
Rating
Schneider Electric
XPSMCMCO0000UB, Schneider Electric
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 673.55
Rohs Verified
PNOZ m ES CANopen, Pilz
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 270.47
Rohs Verified
772119, Pilz
1 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 283.09
Rohs Verified
PNOZ m EF Multi Link, Pilz
4 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 204.52
Rohs Verified
PNOZ m EF 2MM, Pilz
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 389.43
Rohs Verified
PNOZ m ES EtherCAT, Pilz
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 270.47
Rohs Verified
PNOZ ml1p, Pilz
2 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 250.03
Rohs Verified
PNOZ m ES Profinet, Pilz
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 266.46
Rohs Verified
PNOZ ms2p, Pilz
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 642.65
Rohs Verified
PNOZ m EF PDP Link, Pilz
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 197.53
Rohs Verified
PNOZ mc3p Profibus 2, Pilz
17 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 378.55
Rohs Verified
PNOZ mc7p CC-Link, Pilz
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 457.16
Rohs Verified
PNOZ m ES Profibus, Pilz
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 270.47
Rohs Verified
PNOZ m EF 1MM, Pilz
2 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 299.10
Rohs Verified
PNOZ m ES ETH, Pilz
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 165.05
Rohs Verified
PNOZ mc4p DeviceNet 2, Pilz
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 380.30
Rohs Verified
PNOZ m ES EtherNet/IP, Pilz
1 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 312.07
Rohs Verified
UE410-PRO3, Sick
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 292.43
2TLA020071R8000, ABB
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 500.44
Banner
Rohs Verified
SC-IM9A, Banner
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 168.14
Showing
1 -

New Items
New items
XPSMCMCO0000UB, Schneider Electric

XPSMCMCO0000UB, Schneider Electric

Your request could not be completed at this time
New items
PNOZ m ES EtherNet/IP, Pilz

PNOZ m ES EtherNet/IP, Pilz

PNOZmulti 2 Communication/Fieldbus Module EtherNet/IP The PNOZ m ES EtherNet/IP expansion module connects to a base unit from the PNOZmulti 2 configurable control system. Features and Benefits Can be configured in the PNOZmulti Configurator Connection for EtherNet/IP as adapter Transmission rate 10 Mbps (10BaseT) and 100 Mbps (100BaseTX) Status indicators for communication and for errors 128 virtual inputs and outputs on the control system PNOZmulti can be defined in the PNOZmulti Configurator for communication with the fieldbus EtherNet/IP Maximum 1 PNOZ m ES EtherNet/IP can be connected to the base unit 2-port switch Device Level Ring (DLR) Integrated web server Approvals CE, cULus Listed, TÜV, BG, CCC. Supplied with Screw terminals. Safety Controller
New items
PNOZ mc7p CC-Link, Pilz

PNOZ mc7p CC-Link, Pilz

CC-link Expansion Module - PNOZ mc7p Station addresses from 1 to 63 Non-safety related applications Communication with CC-link Occupied stations: 2 Note You will require the PNOZ m1p or PNOZ m0p Approvals UL,CCC Approvals UL,CCC Safety Controller
New items
PNOZ m EF PDP Link, Pilz

PNOZ m EF PDP Link, Pilz

PNOZmulti 2 PDP Link Module The PNOZ m EF PDP Link Expansion Module safely connects decentralised input / output modules (PDP67) to the PNOZmulti 2 configurable control system. Features and Benefits Can be configured in the PNOZmulti Configurator Maximum 4 PNOZ m EF PDP Link can be connected to the base unit Maximum 4 decentralised modules PDP67 F 8 DI ION (VA) or PDP67 F 8 DI ION HP (VA) connect to the link module LEDs for operating state, errors and connection status Approvals CE, cULus Listed, TÜV, BG, CCC. Standards EN ISO 13849-1 PLe; EN ISO 13849-1 Cat. 4; EN 62061 SIL CL 3; IEC 61511 SIL 3. Supplied with Screw terminals. Safety Controller
New items
PNOZ m EF Multi Link, Pilz

PNOZ m EF Multi Link, Pilz

PNOZmulti 2 Multi Link Module The PNOZ m EF Multi Link Module safely connects two PNOZmulti 2 base units. Features and Benefits Connects two PNOZmulti 2 base units Can be configured in the PNOZmulti Configurator Point-to-point connection via 4-core shielded and twisted-pair cable 32 virtual inputs and 32 virtual outputs Status indicators Maximum of 4 PNOZ m EF Multi modules can connect to the base unit LEDs for operating state, errors and connection status Approvals CE, cULus Listed, TÜV, BG, CCC. Standards EN ISO 13849-1 PLe; EN ISO 13849-1 Cat. 4; EN 62061 SIL CL 3; IEC 61511 SIL 3. Supplied with Screw terminals. Safety Controller
New items
PNOZ m EF 1MM, Pilz

PNOZ m EF 1MM, Pilz

PNOZmulti 2 Motion Monitoring Modules The PNOZ m EF *MM expansion module connects to a base unit from the PNOZmulti 2 configurable control system. Two models are available: PNOZ m EF 1MM provides safe monitoring of one axis and PNOZ m EF 2MM provides safe monitoring of two independent axes. Features and Benefits Can be configured in the PNOZmulti Configurator Monitoring of 1 axis, stock no. 918-6617 Monitoring of two independent axes, stock no. 918-6611 Measured value recorded by proximity switch and encoder LED display for supply voltage, diagnostics, axis status and errors Support the safe drive function in accordance with EN 61800-5-2 Applications Safe speed monitoring (SSM) Safe speed range monitoring (SSRM) Safe direction of movement monitoring (SDIM) Safe operating stop monitoring (SOSM) Analogue voltage (track S) Approvals CE, cULus Listed, TÜV, BG, CCC. Standards EN ISO 13849-1 PLe; EN ISO 13849-1 Cat. 4; EN IEC 62061 SIL CL 3; IEC 61511 SIL 3. Supplied with Screw terminals. Safety Controller
New items
772119, Pilz

772119, Pilz

PNOZmulti 2 Communication/Fieldbus Module Powerlink The PNOZ m ES Powerlink expansion module connects to a base unit from the PNOZmulti 2 configurable control system. Features and Benefits Can be configured in the PNOZmulti Configurator Connection for Ethernet POWERLINK (Ethernet POWERLINK V 2 protocol) Station addresses from 1 ... 239, selected via rotary switch The minimum cycle time for an application of 32 B Output and 32 B Input is275μs The minimum cycle time is 500 μs at the maximum PDO size of 254 B Input and 32 B Output 128 virtual inputs and outputs on the control system PNOZmulti can be defined in the PNOZmulti Configurator for communication with the fieldbus Ethernet POWERLINK Maximum 1 PNOZ m ES Powerlink can be connected to the base unit Transmission rate: 100 Mbps Connection to fieldbus via RJ45 connector Approvals CE, cULus Listed, TÜV, BG, CCC. Supplied with Screw terminals. Safety Controller
New items
PNOZ m ES EtherCAT, Pilz

PNOZ m ES EtherCAT, Pilz

PNOZmulti 2 Communication/Fieldbus Module EtherCAT The PNOZ m ES EtherCAT expansion module connects to a base unit from the PNOZmulti 2 configurable control system. Features and Benefits Can be configured in the PNOZmulti Configurator EtherCAT network protocol Supports CANopen over EtherCAT (DS301 V4.02 compliant) Status indicators for communication with EtherCAT and for errors 128 virtual inputs and outputs on the control system PNOZmulti can be defined in the PNOZmulti Configurator for communication with the fieldbus EtherCAT Maximum 1 PNOZ m ES EtherCAT can be connected to the base unit Transmission rate: 100 Mbps Maximum 148 B TxPDO and 20 B RxPDO Connection to fieldbus via RJ45 connector Approvals CE, cULus Listed, TÜV, BG, CCC. Supplied with Screw terminals. Safety Controller
New items
PNOZ ml1p, Pilz

PNOZ ml1p, Pilz

PNOZmulti Safe Link Expansion Module The PNOZ ml1p module is used for the safe connection of two PNOZmulti safety systems. Features and Benefits Can be configured in the PNOZmulti Configurator Point-to-point connection via 4-core shielded twisted-pair cable 32 virtual inputs and 32 virtual outputs Status indicators Plug-in connection terminals Maximum of 4 PNOZ ml1p units can be connected to the base unit LEDs for operating status, error and connection status Approvals CE, cULus Listed, TÜV, BG, CCC, KCC. Standards EN ISO 13849-1 PLe (Cat. 4); EN 954-1 Category Cat. 4; EN IEC 62061 SIL CL 3. Supplied with Screw terminals. Safety Controller
New items
UE410-PRO3, Sick

UE410-PRO3, Sick

UE410 FieldBus Modules, Profibis-DP and DeviceNet Field bus modules can be added to the UE410 FLEXI modular system for diagnostic purposes. They output the system configuration and the input/output states as well as the error and status information of all the modules. All have 4 non-safe diagnostic outputs. Outputs are short circuit protected. Configurable Safety Relay
New items
PNOZ mc3p Profibus 2, Pilz

PNOZ mc3p Profibus 2, Pilz

PNOZmulti Fieldbus Module, Profibus-DP Station addresses from 0 to 99 In accordance with EN50170 non-safety related applications Communication with Profibus-DP Note You will require the PNOZ m1p or PNOZ m0p Approvals UL,CCC Approvals UL,CCC Safety Controller
New items
PNOZ mc4p DeviceNet 2, Pilz

PNOZ mc4p DeviceNet 2, Pilz

PNOZmulti Fieldbus Module, CC-Link Station addresses from 0 to 63 Non-safety related applications Communication with Device-net Note You will require the PNOZ m1p or PNOZ m0p Approvals UL,CCC Approvals UL,CCC Safety Controller
FAQs
We offer free shipping for orders over £200 if delivery is in the UK. All other orders in the UK, shipping from £7.99 depending on the weight and measurement. Mainland Europe shipping charges start from £25. For all other countries shipping charges start from £50 for products like Safety Expansion Modules and all others.
You can email us directly at sales@enrgtech.co.uk or via our website for any queries regarding Safety Expansion Modules or any other product.
This depends on the Safety Expansion Modules individual product and information that can be found on our website.
Yes, we offer special discounts on orders above £200 for Safety Expansion Modules and all other products.
UK orders normally take between 2/3 working days. International orders normally take between 3/5 working days for all products including Safety Expansion Modules.
Yes. We keep updating our stock frequently and if a product like Safety Expansion Modules is not in stock then we will let you know.